Albin RB – Operation Principle
The design is compact and robust, based on well known and proven techniques, with just two moving parts - the rotor and the driven gear.
 |
A
As the rotor shaft is turned the volume of the pockets between the rotor and the gear is increased and a vacuum is created. Liquid enters the suction
B
Observe the progress of the liquid through the pump and how the crescent shape on the head divides the liquid and acts as a seal between the suction and discharge ports. The gear design of the idler and the rotor form locked pockets for the liquid which guarantees absolute volume control.
C
Pump in a completely fl ooded condition in the process of discharging the liquid through the discharge port.
|
|